if no cell/PLMN can be found if the UE is switched on, the UE was never
trying again.
In theory this would be handled by T3410, but the timer
is not started in case the PLMN search isn't done yet.
The current TTI gap calculation assumes strict continuity
of radio time stamps, even when retuning, changing sample rate, etc.
This is certainly desireble but not necessaritly the case and may cause
issues when negative time gaps or too large gaps are detected and reported
to the stack.
this patch makes the assumption that valid TTI jumps are between 1ms
and 1s and that larger gaps are the result of screwed time-stamps
or too long radio operations.
the examples are commented but by just uncommenting those
two lines the user should be able to run a eNB and UE on the same
machine in SISO mode over ZMQ
extend GW-NAS interface to signal test mode activation.
The method is a noop in the normal GW but is implemented in
the TTCN3 DUT according to TS 36.509 for Mode B
This commit implements support for the CLOSE_UE_TEST_LOOP message.
Currently the mode is not saved and looping the data is not implemented.
Only the *_COMPLETE message is sent back as a response.
First of all, with this the NAS conformance tests pass with ciphering and
integrity turned on. Before only integrity was working.
Mainly the NAS was applying the integrity protection and/or ciphering
incorrectly because it wasn't taking the secuirty status of the PDUs
into account. Some where already correct, some not. The patch
streamlines the handling for all outgoing messages.
during deinit of the UE/eNB it could happen that the log_ptr
was already set to null but the stack thread was still accessing
it through log_h->info()
i've moved the old macro into a new header and used as as much
as possible. there are still places in the code where similar
macros are used but we would need to change the variable name
to replace them
previously the NAS would cancel a attach request procedure if the PLMN
is already selected. PLMN selection, however, in not necessarily happening
before requesting RRC to establish a connection.
this is to better differentiate from "send_attach_request" that
only packs and send the actual attach request message. The
entire attach procedure may include PLMN search, etc.
t3402, t3410 and t3411 are now managed in the sender
function of the attach request. previosly they were only
correctly started in the high-level NAS call start_attach_request()
which may not be called if NAS itself resends the request
* Use task id to track old background tasks in RA procedure
* Improve robustness against RF overflow in PHY
* Increase SNR out-of-sync threshold
* Do not change frequency if it's the same
* Increase sync priority
* Increase time to start receiving to reduce input buffer occupation
* Use scoped lock in sf_worker
- move handling to NAS
- use switch off to enable airplane mode (don't wait for EPC response)
- add tiny FSM to control airplane mode activation/deactivation
- only start on/off counter after state has been entered
the signal handler is the same for all three apps. The "running" flag
as well as the file_logger object are in the common header in order
to allow the signal handler to flush the file if the alarm goes off.
The test TC_9_2_1_1_1 sends a Cell->AddOrReconfigure->Basic message
without a "StaticCellInfo" member. This is used to change SIB1 of
the cell and simulate a different PLMN/TAC in the test.
handle_request_cell_basic() ignored the json message if "StaticCellInfo"
is missing which results in the SIB not being updated (PLMN stays as
00102 for example).
With this patch the SIBs after the json are now parsed even if there
"StaticCellInfo" is missing. A confirmation of the json is not sent
because the test does not seem to expect one in that case.
Related: TC_9_2_1_1_1
previously PDCP security (integrity and ciphering) could only
be enabled for both Rx and Tx at the same time.
this, however, caused an issue during the conformance testing in which,
in TC_8_2_1_1() for example, the eNB sends a SecModeCommand and a
RRC Reconfiguration in the same MAC TB. In this case, the eNB
needs to be able to enable DL security right after sending the SecModeCmd
in order to send the RRCReconfig encrypted. However, enabling UL security needs
to be postponed until after the SecModeComplete is received.
This patch allows to enable PDCP security for rx/tx independently if
that is needed. The default way is like before, enabling it for tx/rx at
the same time.
this fixes an issue where commands are received out of
order and we are therefore applying configs incorrectly. if
commands include a timinginfo we are now putting the command
on a queue that the SS reads after the start of a new TTI.
the security and cell reconfig commands will be added in another
PR after the AS_security command has been fixed.
this fixes an issue in the step() function of the connection_request_proc
in which the dedicated_info_nas message was passed to RRC without
checking if its actually valid or not, i.e. contains a message at all.
because this check was missing and the step() function could be called
multiple-times, the function would overwrite the dedicated_info_nas
in RRC, and therefore causing the connection setup complete to fail
this fixes a bug in which the contention resolution timer expired
and the RA proc entered the BACKOFF state.
In the same TTI, a MAC PDU with the contention reslution ID is received
and the already aborted RA procedure succeeds. Unfortunatly with the
wront c-rnti which has already been reset before. See log excerpt
below:
16:16:36.909687 [RRC ] [D] MEAS: Processing measurement of 1 cells
16:16:36.909706 [RRC ] [I] MEAS: New measurement serving cell: rsrp=-85.00 dBm.
16:16:36.909732 [MAC ] [I] [ 6283] RA: ConRes: Contention Resolution Timer expired. Stopping PDCCH Search and going to Response Error
16:16:36.909749 [MAC ] [D] [ 6283] RA: ConRes: Backoff wait interval 143
16:16:36.909771 [MAC ] [D] [ 6282] Delivering PDU=27 bytes to Dissassemble and Demux unit (Temporal C-RNTI)
16:16:36.909799 [MAC ] [D] [ 6283] Found Contention Resolution ID CE
16:16:36.909814 [MAC ] [D] [ 6283] RA: Backof: MAC PDU Contains Contention Resolution ID CE
16:16:36.909826 [MAC ] [D] [ 6283] Msg3 buffer flushed
16:16:36.909858 [MAC ] [I] [ 6283] RA: Backof: Random Access Complete. c-rnti=0x0, ta=0
16:16:36.909871 [MAC ] [D] [ 6283] Saved MAC PDU with Temporal C-RNTI in buffer
this patch adds a buffer len paramter to the receive_samples() call
that protects the (also) provided buffer from overflowing.
currently each call to srslte_ue_sync_zerocopy() which then calls receive_samples()
relies on a buffer that is "big enough". But that buffer is sometimes
2 subframes, sometimes 3 or 5, sometimes has space for the maximum PRB size, sometimes
only for 6 PRBs (i.e. during cell search).
By extending the interface to pass the buffer size we can make sure that
only samples are received that actually fit inside the provided buffer.
If a process exits and has a controlling terminal, everything under
it gets a SIGHUP by the kernel. That's the case for instance when
running a srsUE over ssh with some specific parameters. As a result,
when the ssh client is killed, SIGHUP is sent to srsUE, which will be
killed immediatelly without proper release, which means in turn that log
buffers are not flushed.
Let's do proper shutdown when SIGHUP is received so that everyone can
get log files.
this fixes an issue in which, during cell search, the sync code
itself would set the serving cell whenever it found a new cell.
instead, only report the found cell to RRC and keep the sample
rate at 1.92 MHz. RRC may select a new serving cell and then tell
PHY to camp on it.
rrc_meas refactor. Need to split commit
Fix typo
Temporal commit
Apply rx_gain_offset to neighbour cell measurements
srsLTE: modify TESTASSERT Macro to follow codeline
SRSUE: prevent RRC from having serving cell in neighbour list
SRSUE: DL HARQ does not need Time Aligment Timer. UL is disabled using PUCCH resources release
SRSUE: extend intra-frequency to CA SCell
SRSUE: fix confusing/ambiguous code in the RRC measurements and fix concurrency issue
SRSUE: remove RRC measurement report triggers when measurements are modified or HO succesful
SRSUE: fix compilation issues and Reest SIB indexes
Fixes sync using incorrect cell configuration when search cell does not find a correct cell
Small refactor to remove measurement report triggers always after removing measurement
SRSUE: Removed SIC PSS from UE
SRSUE: fix inter-frequency reestablishment and added more traces
SRSUE: Fix compilation issue
in the UE conformance testing we've spotted an issue
where an event was evaluated even though the trigger type for
the report was periodic which caused an exception in RRC
there were two defaults and one was shadowing the other. This
commit removes both defaults and uses blocking-mode for RRC
calls to PDCP in the UE. The eNB write_sdu() uses the non-blocking
mode by default. We have to review the eNB's RRC perhaps and use blocking
there too and non-blocking only for data plane
previously we've returned the init() function when a sublayer
init failed. This leaves the pointers to the layers unset which, in turn,
breaks the stop() call for the UE
adding a cond variable and mutex to protect init and (re-)config of PHY
currently this is only used during init. If the stack couldn't be
initialized but the PHY init thread was already started, we need to
properly wait until this is done
with the stack refactor we've introduced a regression in which
the GUI was started too early when no cell was found yet.
this caused the GUI to be initilized with only one Tx port. When connecting
to a cell with ports, the GUI plotter would then write
into unitialized memory.
* Clang-formated UE, eNB and lib.
* Fixed compiling errors from clang-format.
* Fix linking issues introduced by clang-format
* Fix poor formating in initializing arrays of arrays.
* Fix mistake in conflict resolution on rm_turbo.c
* Re-apply clang format to gtpc_ies.h
before the type of some message wasn't displayed correctly,
like SIBs, for example because the logger didn't
know the filed to retrieve the type string
the in_sync flag has been misused in some parts of the code
receiving a PHY measurement for a cell does not automatically
mean that we are "in sync", as it is used in RRC as a condition
to indicate if we are camping on cell
the in_sync/out_of_sync condition should only be altered by the
corresponding functions sent from the PHY for the currently selected
cell (and not automatically for all cells)
the commit also removes the deletion of cells which are not "in sync"
from the list of neighbor cells. Instead, RRC calls a clean-up function
peridically that deletes old cells eventually.
move non-type-specific methods of proc_t to its base class.
procedure state machine was simplified via a future-type. Now procedures dont get stuck until the user reads the procedure outcome.
made the NAS procedures more event trigger/reaction-based.
before cell reselection was postponed to the next TTI but this is not possible in
the case where the serving cell changes.
if the "old" serving cell is no longer suitable, we would directly go to RRC IDLE below.
Therefore we need to select the new serving cell before sending the reestablishment
request.
this is tested in TC_8_5_1_1
this allows a simpler main that just signals NAS to switch on the UE
but doesn't block until the action is completed.
For making sure the UE also attached if the first attempt failed
the NAS needs to be extended to support the correct timers.
the main issue was the plmn_selected variable. the solution
was to create a function to enter the deregistered state that resets the variable
and performs all other actions that need to be performed, like clearing
EPS bearers.
The patch also extends the SS to support AT commands to enable/disable
data services and now succesfully passes TC_9_2_2_1_7