during deinit of the UE/eNB it could happen that the log_ptr
was already set to null but the stack thread was still accessing
it through log_h->info()
i've moved the old macro into a new header and used as as much
as possible. there are still places in the code where similar
macros are used but we would need to change the variable name
to replace them
previously the NAS would cancel a attach request procedure if the PLMN
is already selected. PLMN selection, however, in not necessarily happening
before requesting RRC to establish a connection.
this is to better differentiate from "send_attach_request" that
only packs and send the actual attach request message. The
entire attach procedure may include PLMN search, etc.
t3402, t3410 and t3411 are now managed in the sender
function of the attach request. previosly they were only
correctly started in the high-level NAS call start_attach_request()
which may not be called if NAS itself resends the request
* Use task id to track old background tasks in RA procedure
* Improve robustness against RF overflow in PHY
* Increase SNR out-of-sync threshold
* Do not change frequency if it's the same
* Increase sync priority
* Increase time to start receiving to reduce input buffer occupation
* Use scoped lock in sf_worker
- move handling to NAS
- use switch off to enable airplane mode (don't wait for EPC response)
- add tiny FSM to control airplane mode activation/deactivation
- only start on/off counter after state has been entered
the signal handler is the same for all three apps. The "running" flag
as well as the file_logger object are in the common header in order
to allow the signal handler to flush the file if the alarm goes off.
The test TC_9_2_1_1_1 sends a Cell->AddOrReconfigure->Basic message
without a "StaticCellInfo" member. This is used to change SIB1 of
the cell and simulate a different PLMN/TAC in the test.
handle_request_cell_basic() ignored the json message if "StaticCellInfo"
is missing which results in the SIB not being updated (PLMN stays as
00102 for example).
With this patch the SIBs after the json are now parsed even if there
"StaticCellInfo" is missing. A confirmation of the json is not sent
because the test does not seem to expect one in that case.
Related: TC_9_2_1_1_1
previously PDCP security (integrity and ciphering) could only
be enabled for both Rx and Tx at the same time.
this, however, caused an issue during the conformance testing in which,
in TC_8_2_1_1() for example, the eNB sends a SecModeCommand and a
RRC Reconfiguration in the same MAC TB. In this case, the eNB
needs to be able to enable DL security right after sending the SecModeCmd
in order to send the RRCReconfig encrypted. However, enabling UL security needs
to be postponed until after the SecModeComplete is received.
This patch allows to enable PDCP security for rx/tx independently if
that is needed. The default way is like before, enabling it for tx/rx at
the same time.
this fixes an issue where commands are received out of
order and we are therefore applying configs incorrectly. if
commands include a timinginfo we are now putting the command
on a queue that the SS reads after the start of a new TTI.
the security and cell reconfig commands will be added in another
PR after the AS_security command has been fixed.
this fixes an issue in the step() function of the connection_request_proc
in which the dedicated_info_nas message was passed to RRC without
checking if its actually valid or not, i.e. contains a message at all.
because this check was missing and the step() function could be called
multiple-times, the function would overwrite the dedicated_info_nas
in RRC, and therefore causing the connection setup complete to fail
this fixes a bug in which the contention resolution timer expired
and the RA proc entered the BACKOFF state.
In the same TTI, a MAC PDU with the contention reslution ID is received
and the already aborted RA procedure succeeds. Unfortunatly with the
wront c-rnti which has already been reset before. See log excerpt
below:
16:16:36.909687 [RRC ] [D] MEAS: Processing measurement of 1 cells
16:16:36.909706 [RRC ] [I] MEAS: New measurement serving cell: rsrp=-85.00 dBm.
16:16:36.909732 [MAC ] [I] [ 6283] RA: ConRes: Contention Resolution Timer expired. Stopping PDCCH Search and going to Response Error
16:16:36.909749 [MAC ] [D] [ 6283] RA: ConRes: Backoff wait interval 143
16:16:36.909771 [MAC ] [D] [ 6282] Delivering PDU=27 bytes to Dissassemble and Demux unit (Temporal C-RNTI)
16:16:36.909799 [MAC ] [D] [ 6283] Found Contention Resolution ID CE
16:16:36.909814 [MAC ] [D] [ 6283] RA: Backof: MAC PDU Contains Contention Resolution ID CE
16:16:36.909826 [MAC ] [D] [ 6283] Msg3 buffer flushed
16:16:36.909858 [MAC ] [I] [ 6283] RA: Backof: Random Access Complete. c-rnti=0x0, ta=0
16:16:36.909871 [MAC ] [D] [ 6283] Saved MAC PDU with Temporal C-RNTI in buffer
this patch adds a buffer len paramter to the receive_samples() call
that protects the (also) provided buffer from overflowing.
currently each call to srslte_ue_sync_zerocopy() which then calls receive_samples()
relies on a buffer that is "big enough". But that buffer is sometimes
2 subframes, sometimes 3 or 5, sometimes has space for the maximum PRB size, sometimes
only for 6 PRBs (i.e. during cell search).
By extending the interface to pass the buffer size we can make sure that
only samples are received that actually fit inside the provided buffer.
If a process exits and has a controlling terminal, everything under
it gets a SIGHUP by the kernel. That's the case for instance when
running a srsUE over ssh with some specific parameters. As a result,
when the ssh client is killed, SIGHUP is sent to srsUE, which will be
killed immediatelly without proper release, which means in turn that log
buffers are not flushed.
Let's do proper shutdown when SIGHUP is received so that everyone can
get log files.
this fixes an issue in which, during cell search, the sync code
itself would set the serving cell whenever it found a new cell.
instead, only report the found cell to RRC and keep the sample
rate at 1.92 MHz. RRC may select a new serving cell and then tell
PHY to camp on it.