extend GW-NAS interface to signal test mode activation.
The method is a noop in the normal GW but is implemented in
the TTCN3 DUT according to TS 36.509 for Mode B
This commit implements support for the CLOSE_UE_TEST_LOOP message.
Currently the mode is not saved and looping the data is not implemented.
Only the *_COMPLETE message is sent back as a response.
First of all, with this the NAS conformance tests pass with ciphering and
integrity turned on. Before only integrity was working.
Mainly the NAS was applying the integrity protection and/or ciphering
incorrectly because it wasn't taking the secuirty status of the PDUs
into account. Some where already correct, some not. The patch
streamlines the handling for all outgoing messages.
during deinit of the UE/eNB it could happen that the log_ptr
was already set to null but the stack thread was still accessing
it through log_h->info()
i've moved the old macro into a new header and used as as much
as possible. there are still places in the code where similar
macros are used but we would need to change the variable name
to replace them
previously the NAS would cancel a attach request procedure if the PLMN
is already selected. PLMN selection, however, in not necessarily happening
before requesting RRC to establish a connection.
this is to better differentiate from "send_attach_request" that
only packs and send the actual attach request message. The
entire attach procedure may include PLMN search, etc.
t3402, t3410 and t3411 are now managed in the sender
function of the attach request. previosly they were only
correctly started in the high-level NAS call start_attach_request()
which may not be called if NAS itself resends the request