263 Commits (b4b1ab94af30106af15e82337a583844350b3c9b)

Author SHA1 Message Date
Pedro Alvarez 48f9df8615 Applied clang-format to all of the srsepc folder. 5 years ago
Francisco Paisana 67d6a25194 Moving mac timers to stack timers (#638)
* first step towards moving MAC timers to stack. Mac is still using its own timers. srslte::timers class can be restructured.

* moved timers out of the UE MAC
5 years ago
Andre Puschmann 5faa819dcd fixing uninitialized class members found by coverity 6 years ago
Pedro Alvarez b97d1191f4 Added more debug info at eNB GTP-U. Changed the pdcp_entity to follow the standard more strictly for RLC AM DRBs. 6 years ago
Pedro Alvarez 50506ffa26 Changed NAS initialization from init function to constructor. Continuing to add the logic to handle attach request as a Uplink NAS message. Added debug log to s1ap::send_downling_nas_message. 6 years ago
Pedro Alvarez 20ee17088f Starting to add handling of attach request as a Uplink NAS transport message. 6 years ago
Pedro Alvarez d67d18cc6b Removing deplicated error codes. 6 years ago
Andre Puschmann 64dd4c1fc4 fix issue when packing service reject fails and NAS uses initialized logger 6 years ago
Andre Puschmann 4b01a2e4a0 update copyright notice 6 years ago
Andre Puschmann 205db6f229 add missing license headers 6 years ago
Ismael Gomez 7780b1aba5 add tdd/ca support 6 years ago
Pedro Alvarez 1bac758a85 EPC now sends service reject to a UE that sends service request with bad integrity. 6 years ago
Joseph Giovatto fa99aa590e added support for optional ue static ip address (rebase #225) 6 years ago
Pedro Alvarez 3ad19f21b6 Adding per UE authentication algorithm choice to the HSS and users_db.csv. 6 years ago
Pedro Alvarez ca603810ce Adding Downlink data notification and paging functionality to the EPC.
This entails:

  * Adding S1AP paging messaging to the MME.
  * Adding the Downlink Data Notification, Donlink Data Notification Acknoledgment, and Downlink Data Notification Failure Messages.
  * Adding the logic at the GTP-U to detect that Downlink Data notification needs to be sent.
  * Proper handling of the new GTP-C messages at the MME GTPC and SPGW GTPC classes
  * Add queuing mechanisms at the GTP-U while waiting for paging response. Queue is flushed when paging fails (timeout or other).
  * Make sure eNB's SCTP information is properly stored.
  * Make sure UE's GUTI information is properly stored.
6 years ago
Pedro Alvarez 1db959c661 Added NAS timer functionality to the EPC. This entails:
* Adding timer creation at NAS using timerfd_create
  * Adding the ability to add and remove the timer file descriptor to the MME main select loop
  * Adding the ability to the MME for the NAS to check if a timer is running
  * Adding the timer expiry handling functionality at the MME
6 years ago
Pedro Alvarez 9463b95dc1 Remove unused mutex in the SPGW. 6 years ago
Pedro Alvarez 3933b269d7 Added GTP-C message passing between MME and SPGW using UNIX sockets.
* Added S11 sockets to SPGW select and MME select
  * Added send_s11_pdu message to SPGW and MME
  * Remove pointer for replies in handle_s11_pdu
6 years ago
Pedro Alvarez 3e9f10e20d Adding S11 initialization in MME and SPGW as unix sockets. 6 years ago
Pedro Alvarez 5f7b6ba79e Split GTP-C and GTP-U functionality into seperate classes in the SPGW. Added GTP-U specific logging in the EPC. Added handle_s11_pdu function to both the MME GTP-C entity and the SPGW GTP-C entity. 6 years ago
Pedro Alvarez 6e500c5b86 Changed initilization of the NAS at the EPC, to make it easier to add new interfaces. 6 years ago
Pedro Alvarez add60c1288 Applied clang-format to the EPC. 6 years ago
Pedro Alvarez 179aeddfa2 Added encryption of security mode command and attach accept again. Attach is working with encryption. 6 years ago
Pedro Alvarez 997c24c099 Added config of cipher_algo and integ_algo initialization in NAS class. 6 years ago
Pedro Alvarez 5eacdd5418 Fixed compilation issues. Attach failing with COTS UE. 6 years ago
Pedro Alvarez 31a25067f5 Merging David Ruprecth's mme_msg_encryption branch into next. Not compiling. 6 years ago
David Rupprecht c480e57721 Config based security algorithm selection 6 years ago
David Rupprecht e547883a8f Wrapper functions for integrity generate 6 years ago
David Rupprecht 7eef2c1c4b start with decryption function 6 years ago
Andre Puschmann 23836a8ab3 Merge branch 'next' into nas_cleanup 6 years ago
Pedro Alvarez 3cddad79cc Adding ability to configure names of TUN interfaces. (#277)
* added config option for tun dev names vs fixed names added config option for M1-U interface addr

* Added options to sgi_mb tun name.

* Added some comments to mbms.conf.example

* Added some comments to example configs to explain the new values.
6 years ago
Pedro Alvarez 35ca9ffd34 Adding TTL option 6 years ago
Pedro Alvarez 3ecacdf3a6 Adding selection of local interface at the MBMS-GW. 6 years ago
Pedro Alvarez 8dc029cc47 Merging next into NAS cleanup. 6 years ago
Andre Puschmann 860d8af911 Merge branch 'master' into next 6 years ago
Zhe Huang 8b526e1c20 Fix SQN incrementation arithmetic (#212)
* Fix SQN incrementation arithmetic

Current implementation of increment_sqn function increments the 48 bits
SQN directly by 1 which is incorrect according to 3GPP TS 33.102 version
11.5.1 Annex C. This bug causes commercial UEs to report AUTHENTICATION
FAILURE EMM cause #21 "synch failure" when SQN is out of sync.

According to 3GPP TS 33.102 version 11.5.1 Annex C, 48 bits SQN consists
of 43 bits SEQ and 5 bits IND parts where SEQ are incremented during
generation of authentication vector or resync procedure. A
new IND value is also assigned when an authentication vector is
generated. However, resync procedure will use the same IND value.

This patch implements the increment_sqn function according to 3GPP TS
33.102 version 11.5.1 Annex C. A new function increment_seq_after_resync
is added to handle the special case of SQN arithmetic during SQN
resynchronization.

This patch is tested with two comercial UEs (Oneplus One and Oneplus 3T).

* Fix the maximum value of SEQ value to be 2^43-1

The SEQ value is 43 bits long and previous maximum value has a typo (one
extra F) which allows SEQ value to be 2^47-1. This patch corrects the typo.
6 years ago
Pedro Alvarez 9350e03810 Changed detach request and tracking area update request to nas.cc 6 years ago
Pedro Alvarez a9e5b3b8e9 Changed service request to nas.cc 6 years ago
Pedro Alvarez 3337f21ffa Added handle GUTI attach from known UE again. 6 years ago
Pedro Alvarez 0d80ae795b Added IMSI attach from unknown UE as a static function. 6 years ago
Pedro Alvarez 860e1b5491 Changing Handling of initial UE NAS messages to use static methods. Handling of unknown GUTI attach request should be ok. 6 years ago
Pedro Alvarez 9e808ff968 Starting to handle NAS initial UE messages as static methods of the nas class. 6 years ago
Pedro Alvarez e3286897ce Changed the rest of the nas handling to use send_downlink_nas_transport. 6 years ago
Pedro Alvarez f1d30c7f23 Changed handle guti_attach_from_known_ue and unknown_ue to use send_downstream_nas_message. 6 years ago
Pedro Alvarez dd725be60c Changed pack identity request. 6 years ago
Pedro Alvarez 65a5139751 Fixed mistake in downlink nas transport. Changing authication request to use downlink_nas_transport. 6 years ago
Pedro Alvarez 21c34b9ce5 Changing security mode complete to use downlink nas transport 6 years ago
Pedro Alvarez 93222f582c Changed authentication response to use downlink_nas_transport(). 6 years ago
Pedro Alvarez 3073ab6822 Changed dettach request to use downlink nas transport. 6 years ago
Pedro Alvarez 749e84315a Starting to add send_downlink_nas_transport helper function. 6 years ago