8 Commits (936e3b7bef8890ef5ff0d075e64d63e9ad6e3d3e)

Author SHA1 Message Date
Andre Puschmann 1afc137032
[REBASE] Make PHY non-blocking and fefactor HO procedure (#1753)
* Make PHY non-blocking and fefactor HO procedure

* makes entire PHY non-blocking through command interface
* adds dedicated queue for cell_search/cell_select commands
* refactor HO procedure to run faster, in one stack cycle. Looks closer to the specs
* force ue to always apply SIB2 configuration during reestablishment
* Run update_measurements in all workers

Co-authored-by: Ismael Gomez <ismagom@gmail.com>
4 years ago
Andre Puschmann 6827c2df21 rrc_meas: disable layer3 filtering until quantity config is received
the filter alpha was initialized to zero by default which causes an
issue because the first measurement for a cell can't be updated,
because the filtering function will always return the current value.

According to 36.331 Sec 5.5.3.2 Note 2, a k-value of 0 should turn
off filtering, which should be used as the default value until
an update is received from the network.
4 years ago
Ismael Gomez f49fbd6d02
Fix the order of HO/reest measurement actions (#1696) 4 years ago
Francisco Paisana 82cb6baef0 now the whole ue and enb mac uses the logmap 5 years ago
Francisco Paisana d3f49d0e3c changed interface sync-stack to allow tti jumps > 1 5 years ago
Xavier Arteaga e832769ae6 Updated copyright 5 years ago
Francisco Paisana c29f08d8d5 refactored si acquisition procedure to use stack timers. Also created an interface that is going to be used for the task/timer handling 5 years ago
Ismael Gomez 52716f8716 Process HO complete in the background to avoid heap-after-use bug when PHY measurements are reported during a HO
rrc_meas refactor. Need to split commit

Fix typo

Temporal commit

Apply rx_gain_offset to neighbour cell measurements

srsLTE: modify TESTASSERT Macro to follow codeline

SRSUE: prevent RRC from having serving cell in neighbour list

SRSUE: DL HARQ does not need Time Aligment Timer. UL is disabled using PUCCH resources release

SRSUE: extend intra-frequency to CA SCell

SRSUE: fix confusing/ambiguous code in the RRC measurements and fix concurrency issue

SRSUE: remove RRC measurement report triggers when measurements are modified or HO succesful

SRSUE: fix compilation issues and Reest SIB indexes

Fixes sync using incorrect cell configuration when search cell does not find a correct cell

Small refactor to remove measurement report triggers always after removing measurement

SRSUE: Removed SIC PSS from UE

SRSUE: fix inter-frequency reestablishment and added more traces

SRSUE: Fix compilation issue
5 years ago