- add tx/rx softbuffers for each CC that a UE might have
- make sure to call assign correct buffers when iterating
over the CC for UL/DL grant assignment
Avoid double buffering of SIBs in MAC as this would require one buffer for each CC.
Instead, use byte_buffer managed by RRC that contains packed SIBs to avoid
double memcpy for each SIB tx. Only use MAC provided buffer in error case.
Also avoid MAC calling RLC for each SIB and call RRC directly.
- move cell specific eNB params to cell list in rr.conf
- make sure DL EARFCN and DL freq can be used to manually overwrite a single cell config
- fix SIB packing and transmission for multi cell configs
- introduce cell list to MAC
- adapt default enb.conf.example and rr.conf.example
previously PDCP security (integrity and ciphering) could only
be enabled for both Rx and Tx at the same time.
this, however, caused an issue during the conformance testing in which,
in TC_8_2_1_1() for example, the eNB sends a SecModeCommand and a
RRC Reconfiguration in the same MAC TB. In this case, the eNB
needs to be able to enable DL security right after sending the SecModeCmd
in order to send the RRCReconfig encrypted. However, enabling UL security needs
to be postponed until after the SecModeComplete is received.
This patch allows to enable PDCP security for rx/tx independently if
that is needed. The default way is like before, enabling it for tx/rx at
the same time.
rrc_meas refactor. Need to split commit
Fix typo
Temporal commit
Apply rx_gain_offset to neighbour cell measurements
srsLTE: modify TESTASSERT Macro to follow codeline
SRSUE: prevent RRC from having serving cell in neighbour list
SRSUE: DL HARQ does not need Time Aligment Timer. UL is disabled using PUCCH resources release
SRSUE: extend intra-frequency to CA SCell
SRSUE: fix confusing/ambiguous code in the RRC measurements and fix concurrency issue
SRSUE: remove RRC measurement report triggers when measurements are modified or HO succesful
SRSUE: fix compilation issues and Reest SIB indexes
Fixes sync using incorrect cell configuration when search cell does not find a correct cell
Small refactor to remove measurement report triggers always after removing measurement
SRSUE: Removed SIC PSS from UE
SRSUE: fix inter-frequency reestablishment and added more traces
SRSUE: Fix compilation issue