the main issue was the plmn_selected variable. the solution
was to create a function to enter the deregistered state that resets the variable
and performs all other actions that need to be performed, like clearing
EPS bearers.
The patch also extends the SS to support AT commands to enable/disable
data services and now succesfully passes TC_9_2_2_1_7
this fixes the issue when the stack is torn down if, for example,
the radio couldn't be loaded correctly. it will hence call stop() on all stack
components which are not initialzized yet, and logging therefore doesn't work.
the log object is know during contruction time and therefore can be passed
in as soon as possible.
- abstract UE object now consists of a radio, a PHY, and a stack layer
- add new stack abstraction layer that combines MAC, RLC, RRC, PDCP, NAS and GW
- PHY layer now has a single stack interface and does not talk to MAC and RRC seperatly