gnb,rrc: inverse order of configuring lower layers when establishing bearer

start with lower layers first, so MAC, RLC then PDCP.
Since PDCP requires that the LCID is already registered at RLC to make config
checks. It checks for RLC mode (UM) in this case causing log entries like:

2021-12-01T13:47:40.453641 [RLC-NR ] [W] LCID 4 doesn't exist.
master
Andre Puschmann 3 years ago
parent a27562cb58
commit 091877fd2a

@ -1073,14 +1073,14 @@ void rrc_nr::ue::send_rrc_reconfiguration()
}
// Update lower layers
// add PDCP bearers
update_pdcp_bearers(ies.radio_bearer_cfg, master_cell_group);
// add MAC bearers
update_mac(master_cell_group, false);
// add RLC bearers
update_rlc_bearers(master_cell_group);
// add MAC bearers
update_mac(master_cell_group, false);
// add PDCP bearers
update_pdcp_bearers(ies.radio_bearer_cfg, master_cell_group);
}
if (nas_pdu_queue.size() > 0) {